Ruggedization levels

ApisSys products support up to four ruggedization levels, ranging from standard air flow for development and benign environment use to rugged conduction cooled dedicated to deployed defense applications in harsh environment.

  Air flow, Standard
AS (VITA 47 EAC4* 
Air flow, Rugged
AR (VITA 47 EAC6)* 
Conduction Standard
CS (VITA 47 ECC3)* 
Conduction Rugged
CR (VITA47 ECC4)* 
Operating
Temperature
0°C to +55°C (1)
(8 CFM airfl ow at sea level)
-40 to +70ºC (1)
(8 CFM airfl ow at sea level)
-40°C to +70°C
(Card Edge)
-40°C to +85°C
(Card Edge)
Non Operating Temperature -40°C to +85°C -50°C to +100°C -50°C to +100°C -55°C to +105°C
Operating
Vibration
(Random)
5Hz - 100Hz +3 dB/octave
100Hz-1kHz = 0.04 g2/Hz
1kHz - 2kHz -6 dB/octave
5Hz - 100Hz +3 dB/octave
100Hz - 1kHz = 0.04 g2/Hz
1kHz - 2kHz -6 dB/octave
5Hz - 100Hz +3 dB/octave
100Hz - 1kHz = 0.1 g2/Hz
1kHz - 2kHz -6 dB/octave
5Hz - 100Hz +3 dB/octave
100Hz - 1kHz = 0.1 g2/Hz
1kHz - 2kHz -6 dB/octave
Operating Shock 20g, 11 millisecond, half-sine 20g, 11 millisecond, half-sine 40g, 11 millisecond, half-sine 40g, 11 millisecond, half-sine
Operating
Relative Humidity
0% to 95%
non-condensing
0% to 95%
non-condensing
0% to 95%
non-condensing
0% to 95%
non-condensing
Operating
Altitude
@ 0 to 10,000 ft
with adequate airflow
@ 0 to 30,000 ft
with adequate airflow
@ 0 to 30,000 ft @ 0 to 60, 000 ft
Conformal Coating No Optional (default acrylic 1B31) Yes (default acrylic 1B31) Yes (default acrylic 1B31)

*Reference to ANSI-VITA standard VITA 47 (r2) for the listed parameters only. Temperature cycling or other not listed VITA 47 requirements on demand